Home / Products / YJV, YJLV and YJV22 power cables

KANGYIDA SUPPLY

YJV, YJLV and YJV22 power cables

YJV / YJLV / YJV22

Compare three XLPE/PVC power cable options for 0.6/1 kV distribution: copper YJV, aluminium YJLV and copper YJV22 with steel tape armour. Start with conductor material and mechanical protection, then specify core count, cross-section and installation conditions. The order specification confirms the selected supply configuration.

YJV, YJLV and YJV22 power cables
YJV / YJLV / YJV22

Choose a model to enquire

YJV

Copper conductor with XLPE insulation and a PVC sheath. Specify the unarmoured group when it matches the route design and protection requirements.

Request a quote · YJV

YJLV

Aluminium conductor with XLPE insulation and a PVC sheath. Check resistance, weight and terminations separately rather than copying the YJV specification.

Request a quote · YJLV

YJV22

A copper-conductor option with steel tape armour. Include mechanical conditions and installation method to identify the appropriate configuration.

Request a quote · YJV22

Applications and requirements

  • Low-voltage distribution circuits and fixed power feeders, subject to the project design.
  • Indoor routes, tunnels and cable trenches: compare YJV and YJLV against the conductor and installation requirements.
  • Routes requiring steel tape mechanical protection: assess YJV22 against the actual burial, routing and pulling conditions.

Technical information to check

YJV, YJLV and YJV22 power cables
YJVCopper conductor / XLPE insulation / PVC sheath; unarmoured in the group described here.
YJLVAluminium conductor / XLPE insulation / PVC sheath; requires its own resistance, weight and termination specification.
YJV22Copper conductor / XLPE / filling and bedding / steel tape armour / PVC sheath.
Documented voltage group0.6/1 kV. Medium-voltage enquiries require a separate technical specification.
Documented configurationsYJV/YJLV tables include 1–5 cores and specific 3+1, 3+2 and 4+1 combinations. One YJV22 example is 3×120+1×70 mm²; a size range does not imply every core combination.
YJV/YJLV reference standardsThe reviewed low-voltage sheet cites GB/T 12706.1-2020 and IEC 60502-1:2004. Confirm the applicable edition for the order.

What to include in your enquiry

  • Specify YJV, YJLV or YJV22 and the conductor material.
  • Give rated voltage U₀/U, core count, each core cross-section and total length.
  • Describe installation method, ambient temperature, grouping and mechanical protection requirements.
  • Agree the dated specification, applicable standards and batch configuration performance before ordering.

Buying guide · Request a quote

Frequently asked questions

What is the difference between YJV and YJLV?

The main difference is conductor material: YJV uses copper and YJLV uses aluminium. Both have XLPE/PVC construction in this group, but their resistance, weight and termination requirements differ. State the conductor material explicitly in the purchase specification.

When should I consider YJV22?

YJV22 adds steel tape armour for routes requiring mechanical protection. The reviewed document describes tunnel, trench and direct-burial use, while excluding high pulling loads. Check the actual installation conditions before selecting an armoured configuration.

Can I use the 0.6/1 kV data for medium-voltage cables?

No. Medium-voltage insulation, screening and test data require a separate review. Include rated voltage U₀/U, core count and cross-section in the enquiry; the low-voltage construction shown here does not describe the full range up to 35 kV.